Influence of suspension liquid total solids on E. coli O157

Oleksandr Tokarskyy, Mykhaylo Korda

Influence of suspension liquid total solids on E. coli O157

Číslo: 1/2019
Periodikum: Potravinárstvo
DOI: 10.5219/1210

Klíčová slova: tomatoes, cardboard, E. coli O157:H7, survival, transfer, cross-contamination, ATP luciferase test

Pro získání musíte mít účet v Citace PRO.

Přečíst po přihlášení

Anotace: The objectives of this study were: a) to determine E. coli O157:H7 survival on tomatoes and cardboard squares post-drying, stored at 25 ºC in humidified environment for four days, in buffered peptone water (BPW), and 0.1% diluted peptone (DP); b) to determine pathogen transfer rates (0, 1.5, or 24-hours drying post-inoculation), from inoculated tomato surfaces to uninoculated cardboard squares and conversely; and c) to evaluate SystemSure Plus ATP luminometer for recognizing contamination on visibly soiled (BPW) or visible clean (DP) cardboard. In tomato inoculation studies, E. coli O157:H7 survived better on the fruit when the inoculum was prepared using DP as compared to BPW. The 1.5-hours post drying counts of 5.34 and 5.76 log10 CFU.mL-1 in the rinsate substantially declined to 1.45 and 1.17 log10 CFU.mL-1 on day four, for DP and BPW, respectively. In cardboard inoculation studies, E. coli O157:H7 persisted for four days, with 1.5-hours post-drying counts and day four counts of 4.53 (DP) and 2.55 log10 CFU.mL-1 (BPW), contrary to 3.81 (DP) and 1.92 log10 CFU.mL-1 (BPW). Under the first impression, the slower die-off of E. coli O157:H7 on cardboard questions the possibility of reusing cardboard boxes due to the potential for cross-contamination. In wet transfer (0 hour drying) trials, both tomato-to-cardboard and cardboard-to-tomato yielded 100% positive transfers irrespective of diluent type. Dry transfer (1.5-hours drying interval post inoculation) from tomato-to-cardboard were 100% positive, but no positives were noted when inoculated, dried cardboard was contacted to tomatoes, irrespective of diluent. Results of transfers with BPW as the diluent showed 100% positive transfer from 24-hours dry tomatoes-to-cardboard, as inoculation spots on the tomatoes remained moist due to hygroscopic nature of solutes in BPW. Conversely, only a 40% positive transfer rate was observed under the same conditions with DP as diluent. No positive transfers were recorded from 24-hours dry cardboard-to-tomatoes, irrespective of diluent type. Though E. coli O157:H7 survived better on the surface of cardboard compared to the surface of tomatoes on day four, the dry transfers were more efficient from tomatoes-to-cardboard than conversely, possibly due to smooth and hydrophobic properties of the tomato, and rough and porous surface of the cardboard. ATP luciferase UltrasnapTM swab test showed 9/9 “pass” results for sterile liquid DP and BPW, while 9/9 “fail” results were observed with liquid peptone and BPW contaminated at ca. 9.0 log10 CFU.mL-1E. coli O157:H7. Cardboard squares treated and dried, with sterile DP, showed 8/9 “pass” ATP luciferase results, and 1/9 “warning”, while cardboard squares with contaminated DP showed 9/9 “fail” result. Cardboard squares treated and dried, with sterile BPW, showed 7/9 “pass” ATP luciferase results, and 2/9 “warning”, while cardboard squares with contaminated BPW showed 9/9 “fail” result. Luminometer can simplify detection of microbial load, as well as organic residues, helping to check cardboard boxes for cleanness.