Finite element analysis of mechanical properties of specimen with uhpc and stud connector

Long Liu, Songqiang Wan, Shuwen Yao, Xinzhen Zhao, Jinyan Ma

Finite element analysis of mechanical properties of specimen with uhpc and stud connector

Číslo: 1/2022
Periodikum: Civil Engineering Journal
DOI: 10.14311/CEJ.2022.01.0008

Klíčová slova: Push out test, UHPC, Stud connector, Finite element, Reinforcement

Pro získání musíte mít účet v Citace PRO.

Přečíst po přihlášení

Anotace: UHPC is different from ordinary concrete for mechanical properties. To study the stress state of stud connector when UHPC is used to strengthen RC beam and its influence on bearing capacity of the strengthened beam, in this paper, ABAQUS was adopted first to simulate the push-out test of stud to verify accuracy of the finite element model. The nonlinearity of materials and contact conditions was considered in the model, and then three parameters including concrete strength, stud length and stud diameter were studied. Results showed the finite element model established by surface to surface contact method was possible to simulate the force and failure of the stud connector. UHPC could improve the bearing capacity of the stud specimens obviously, and the length of stud had little effect on bearing capacity of stud while failure of the stud may occur if length of the stud was too small. The increase of stud diameter could improve bearing capacity of elastic working stage.