The characterization of anodic oxide layers on selected bio-compatible titanium alloys

Jan Krčil, Vladimír Mára, Stanislav Krum, Jana Sobotová

The characterization of anodic oxide layers on selected bio-compatible titanium alloys

Číslo: 4/2018
Periodikum: Acta Polytechnica
DOI: 10.14311/AP.2018.58.0240

Klíčová slova: titanium; niobium; TiNb; anodic oxidation; oxide layers; surfaces, titan; niobium; TiNb; anodická oxidace; oxidové vrstvy; povrchy

Pro získání musíte mít účet v Citace PRO.

Přečíst po přihlášení

Anotace: Oxide layers on titanium alloy surfaces have an influence on bio-compatibility and corrosion resistance. In order to improve them, properties of oxide layers are examined. The oxide layer can be prepared by different methods and under various conditions. This results in a creation of layers showing different composition, structure, properties, stability, adhesion and biocompatibility. In the presented paper, samples of three titanium alloys were used: Commercially Pure (CP) titanium grade 2, Ti6Al4V alloy and -titanium alloy Ti-39 wt.% Nb. Samples were anodically (1MH2SO4 / 100V/ 1 hour) oxidized. Changes in surface colouration and roughness were observed. The thickness of oxide layers was measured using a scanning electron microscope (SEM). The SEM was then used for observation of the surface topography of oxidized samples. The chemical composition of the surface layers was defined by X-ray photoelectron spectroscopy (XPS).