Analyzing the Resonance Resultant from the Capacitive Effects in Bulk Current Injection Probe

I. M. Mashriki, S. M. J. Razavi, S. H. M. Armaki

Analyzing the Resonance Resultant from the Capacitive Effects in Bulk Current Injection Probe

Číslo: 1/2020
Periodikum: Radioengineering Journal
DOI: 10.13164/re.2020.0109

Klíčová slova: Bulk current injection (BCI) probe, electromagnetic compatibility (EMC), shield effect, slot capacitance, dielectric constant of ferrite

Pro získání musíte mít účet v Citace PRO.

Přečíst po přihlášení

Anotace: In this paper, the effect of the slot distance, existed between the two parts of BCI-probe shield, on its performance is studied, therefore, two ferrite materials with the same size and different characteristics are used to implement two identical BCI-probes. The input impedance and reflection coefficient are measured for four different values of slot distance 0.5, 1, 2 and 3 mm. Practical results show a notable effect of the slot distance on measured quantities. Measured impedance analysis shows the appearance of three capacitive regions in its spectra, therefore, a three dimensional electromagnetic (EM) model is implemented in CST-Microwave Studio (MWS) software to disclose the main source parameters responsible for it. Results of achieved study, using developed EM model, were in accordance with measured data for the implemented prototypes, and showed the same resonance phenomena.